What are the UL94 test methods for flame retardancy of silicone foam boards?

Sep 10, 2025 Leave a message

  The UL94 flame retardant test method is a standardized test procedure used to evaluate the burning behavior of silicone foam and other materials.

 

  UL94 classifies fire resistance grades into 12 levels, including HB, V-0 to V-2, 5VA/5VB, etc. Among them, the VTM series is suitable for plastic films, and the HBF series is for foamed materials. The testing methods include six schemes such as horizontal burning, vertical burning, and 5V level flame testing. For instance, the V-0 level requires that the sample flame self-extinguish within 10 seconds after removal and the molten droplets do not ignite the cotton below. The 5VA/5VB level needs to withstand five 125mm flame impacts without molten droplets or structural damage. The standard references multiple material testing specifications such as ASTM D618 and D5025, and determines the grade through parameters such as burning time and droplet behavior.

 

UL94 has a total of 12 fire resistance ratings: HB, V-0, V-1, V-2, 5VA, 5VB, VTM-0, VTM-1, VTM-2, HBF, HF1, HF2. Among them, VTM-0, VTM-1 and VTM-2 are suitable for plastic films, while HBF, HF1 and HF2 are suitable for foam materials.

 

HB flame retardant silicone sponge1

The grading test plan is as follows:

  (1) HB grade: Horizontal Burning Test

  (2) V0-V2 grade: Vertical Burning Test

  (3) 5VA/5VB: 5V Class fire resistance Test 500w (125mm) Vertical Burning Test

  (4) RP Class: Radiant Panel Flame Spread Test

  (5) VTM0-VTM2: Thin Material Vertical Burning Test

  (6) HF1-HF2: Horizontal Burning Foamed Material Test

 

The specific test requirements for UL94 are as follows:

  HB: The flame retardant grade in the UL94 standard. For samples with a thickness of 3 to 13 millimeters, the burning rate should be less than 40 millimeters per minute. For samples less than 3 millimeters thick, the burning speed is less than 70 millimeters per minute. Or extinguish it in front of the 100-millimeter mark.

   V-0: After conducting two 10-second burning tests on the sample, the afterflame and afterburn were extinguished within 30 seconds. The dripping particles cannot ignite cotton.

   V-1: After conducting two 10-second burning tests on the sample, the afterflame and afterburn were extinguished within 60 seconds. The dripping particles cannot ignite cotton.

   V-2: After conducting two 10-second burning tests on the sample, the afterflame and afterburn were extinguished within 60 seconds. The dripping particles can ignite cotton.

   5VB: After conducting five 5-second burning tests on the sample, the afterflame and afterburn were extinguished within 60 seconds. The dripping particles cannot ignite cotton. For block-shaped samples, burn-through is allowed.

  5VA: After conducting five 5-second burning tests on the sample, the residual flame and smolder were extinguished within 30 seconds. The dripping particles cannot ignite cotton. Lump-shaped samples are not allowed to be burned through.